Automated Glucose Values Boost Accuracy of Insulin Infusion Calculators

By Marcus A. Banks

Insulin infusion calculators at the Cleveland Clinic Health System automatically account for the blood glucose values of patients in intensive care, before an infusion begins, as described in a new report in the Journal of the American College of Clinical Pharmacy

Intensive care nurses previously entered glucose values to calculate initial dose and dose adjustments manually, potentially with transcription errors that lowered the accuracy of the